144,35 €
Schneider Electric LC1D is a three-pole electromagnetic contactor engineered for switching and control of AC circuits in industrial and commercial installations. The device provides reliable make-and-break operation for motors, lighting and general power loads. With a rated insulation voltage of 600... Leer más
Stock 5 Código 2564640 Marca APC Modelo LC1D32P7 Garantía 3 años

Envíos y devoluciones

Entrega estimada jueves, 29 de octubre
Te mantendremos informado a través de nuestro sistema de seguimiento detallado
Opciones de pago
Tarjeta bancariaVisaMastercardPayPalApple PayGoogle PayTransferencia bancaria

Schneider Electric LC1D is a three-pole electromagnetic contactor engineered for switching and control of AC circuits in industrial and commercial installations. The device provides reliable make-and-break operation for motors, lighting and general power loads. With a rated insulation voltage of 600 V and an impulse withstand voltage of 6 kV, this compact contactor measures 45 mm wide, 92 mm deep and 85 mm high, making it suitable for installation in distribution boards and control panels with limited space.

Advantages

The LC1D contactor combines a compact footprint with robust electrical characteristics, offering stable switching performance and a high rated insulation level for safety in harsh electrical environments. Its three-pole construction supports three-phase load switching while the standardized dimensions simplify panel mounting and replacement of similar modular contactors. The product is compatible with typical auxiliary and control circuit accessories used in motor starters and lighting control systems.

Suitable for

  • Three-phase motor starters and soft starter bypass switching
  • Switching and control of industrial and commercial lighting circuits
  • General-purpose switching of resistive and inductive loads within rated voltages
  • Control panels and distribution boards with space constraints

Key specifications

  • Poles: 3-pole configuration for three-phase circuits
  • Rated insulation voltage: 600 V suitable for typical industrial AC systems
  • Rated impulse withstand voltage (Uimp): 6 kV for transient overvoltage resistance
  • Dimensions (W×D×H): 45 × 92 × 85 mm for compact panel installation
  • Electromechanical operation: electromagnetic contactor suitable for AC switching tasks

How to use

Mount the contactor on a DIN rail or panel according to local electrical codes and the enclosure layout, ensuring adequate clearance for ventilation and wiring. Connect the three input and three output power conductors to the main poles and wire the control coil to the appropriate control circuit voltage. Verify that the system voltage and anticipated transient levels do not exceed the contactor's rated insulation and impulse withstand voltages. Perform functional checks by energizing the coil and observing correct make-and-break operation before placing the contactor into continuous service.

Recommendations

Use the contactor within its rated voltage limits and pair it with suitable overload protection and auxiliary devices when used for motor control. Periodically inspect contactor contacts and terminal connections for wear and tightness in accordance with maintenance schedules to ensure long-term reliable operation.

Aspectos destacados
  • Three-phase motor starters and soft starter bypass switching
  • Switching and control of industrial and commercial lighting circuits
  • General-purpose switching of resistive and inductive loads within rated voltages
  • Control panels and distribution boards with space constraints
  • Poles: 3-pole configuration for three-phase circuits
  • Rated insulation voltage: 600 V suitable for typical industrial AC systems
  • Rated impulse withstand voltage (Uimp): 6 kV for transient overvoltage resistance
  • Dimensions (W×D×H): 45 × 92 × 85 mm for compact panel installation
  • Electromechanical operation: electromagnetic contactor suitable for AC switching tasks
Especificaciones
Altitud máxima de funcionamiento
3000 m
Altura
85 mm
Altura del embalaje
50 mm
Ancho
45 mm
Ancho del embalaje
112 mm
Categoría de sobretensión
CAT III
Corriente de irrupción máxima
32 A
Durabilidad eléctrica (ciclos)
1650000
Durabilidad mecánica (ciclos)
15000000
Frecuencia de entrada
25 - 400
Número de polos
3P
Periodo de garantía
1.5 year(s)
Peso
0.375 kg
Peso del embalaje
413 g
Profundidad
92 mm
Profundidad del embalaje
92 mm
Resistencia al fuego
850 °C
Temperatura de almacenamiento (T-T)
-60 - 80
Tensión nominal de aislamiento
600 V
Tensión nominal de entrada
690
Tensión nominal de impulso soportada (Uimp)
6 kV

Folleto

Abrir documento
Historial de precios de los últimos 6 meses
Contactor Schneider Electric LC1D, 3 polos, tensión nominal de aislamiento 600 V, Uimp 6 kV, 45×92×85 mm
Actual
144,35 €
Mínimo
142,38 €
Máximo
166,02 €
Variación 24 h
+0,43 €   +0%
Semana
-1,53 €   -1%
Mes
-2,47 €   -2%

Escribir una opinión

Valoración *
Tu nombre se mostrará públicamente: puedes usar un apodo. Invitamos a los compradores a escribir opiniones; las revisamos antes de publicarlas y publicamos también las críticas.

Productos populares en esta categoría

Vendedor: UAB KUR LT · Laisvės pr. 125A, LT-06118 Vilna, Lituania · Código de empresa 303192950 · NIF-IVA UE LT100008198612 · Envío desde la UE (Lituania)
Hola, soy el asistente de IA de DistriNode. Puedo ayudarte a encontrar productos, comparar opciones, crear presupuestos en PDF o abrir solicitudes de soporte.
Todas las categorías