APC Rack PDU 2G, Metered by Outlet con conmutación, ZeroU, 32A, 230V, (21) C13 y (3) C19

APC Rack PDU 2G, Metered by Outlet con conmutación, ZeroU, 32A, 230V, (21) C13 y (3) C19
APC Rack PDU 2G, Metered by Outlet con conmutación, ZeroU, 32A, 230V, (21) C13 y (3) C19
APC Rack PDU 2G, Metered by Outlet con conmutación, ZeroU, 32A, 230V, (21) C13 y (3) C19
APC Rack PDU 2G, Metered by Outlet con conmutación, ZeroU, 32A, 230V, (21) C13 y (3) C19
APC Rack PDU 2G, Metered by Outlet con conmutación, ZeroU, 32A, 230V, (21) C13 y (3) C19
APC Rack PDU 2G, Metered by Outlet con conmutación, ZeroU, 32A, 230V, (21) C13 y (3) C19
APC Rack PDU 2G, Metered by Outlet con conmutación, ZeroU, 32A, 230V, (21) C13 y (3) C19
APC Rack PDU 2G, Metered by Outlet con conmutación, ZeroU, 32A, 230V, (21) C13 y (3) C19
2.091,48 €
The APC Switched Rack PDU AP8653 is a 0U rack-mount power distribution unit designed for data center and network cabinets. It provides 24 AC outlets and a fixed 3 m input cable for single-phase power distribution with a nominal input voltage of 230 V and a maximum current rating of 32 A. The unit co... Leer más
Stock 78 Código 2408190 Marca APC Modelo AP8653 Garantía 2 años

Envíos y devoluciones

Entrega estimada Martes, Octubre 20
Te mantendremos informado a través de nuestro sistema de seguimiento detallado
Opciones de pago
Tarjeta bancariaVisaMastercardPayPalApple PayGoogle PayTransferencia bancaria

The APC Switched Rack PDU AP8653 is a 0U rack-mount power distribution unit designed for data center and network cabinets. It provides 24 AC outlets and a fixed 3 m input cable for single-phase power distribution with a nominal input voltage of 230 V and a maximum current rating of 32 A. The unit combines switched outlet control and metering capabilities to monitor current, power and voltage at the device level and at individual outlets, and includes temperature/humidity sensor support and locking IEC receptacles for secure connections.

Advantages

The AP8653 offers per-outlet switching and metering so administrators can remotely power on, power off, or recycle individual devices and track real-time load data. Built-in current and power monitoring helps prevent circuit overloads and supports user-defined alarms. The 0U form factor preserves rack space while 24 outlets provide dense power distribution. Certified to EN standards and delivered in a rack-ready configuration with mounting brackets, locking IEC receptacles and configuration accessories, the unit facilitates secure, manageable and auditable power control.

Suitable for

  • Racks and cabinets in data centers and server rooms
  • Network closets and telecom equipment racks
  • Environments requiring remote outlet control and power metering
  • Installations that need sequence-controlled power-up or prioritized load shedding

Key specifications

  • Nominal input voltage: 230 V
  • Maximum current: 32 A
  • AC outlets quantity: 24 outlets
  • PDU type: Switched, Metered
  • Form factor: 0U rack-mount
  • Cable length: 3 m fixed input cable
  • Monitoring: current, power and voltage metering
  • Environmental support: temperature/humidity sensor port
  • Security: locking IEC receptacles
  • Colour: Black
  • Weight: 8.23 kg

How to use

Install the AP8653 in a compatible rack using the supplied mounting brackets in a 0U position to preserve vertical rack space. Connect the 3 m input cable to an appropriate single-phase 230 V supply rated for up to 32 A. Configure network access through the device web interface, SNMP or Telnet, and attach the optional temperature/humidity sensor if environmental monitoring is needed. Use the management interface to set outlet control permissions, power sequencing delays and alarm thresholds, and to view real-time metered values for current, voltage and active power.

Recommendations

To minimize risk of overload, verify total connected load does not exceed the 32 A maximum and use the per-outlet metering to balance loads. Implement access controls and locking IEC cords to prevent unauthorized power changes, and define power-up sequences for dependent equipment to avoid inrush current conflicts during recovery events.

Aspectos destacados
  • Racks and cabinets in data centers and server rooms
  • Network closets and telecom equipment racks
  • Environments requiring remote outlet control and power metering
  • Installations that need sequence-controlled power-up or prioritized load shedding
  • Nominal input voltage: 230 V
  • Maximum current: 32 A
  • AC outlets quantity: 24 outlets
  • PDU type: Switched, Metered
  • Form factor: 0U rack-mount
  • Cable length: 3 m fixed input cable
  • Monitoring: current, power and voltage metering
  • Environmental support: temperature/humidity sensor port
  • Security: locking IEC receptacles
  • Colour: Black
  • Weight: 8.23 kg
Especificaciones
Altitud de funcionamiento
0 - 3000 m
Altitud fuera de funcionamiento
0 - 15000 m
Altura
1829 mm
Altura del embalaje
2038 mm
Ancho
56 mm
Ancho del embalaje
162 mm
Capacidad de carga
7680 VA
Capacidad del rack
0U
Certificación
EN 55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3, VDE
Certificados de conformidad
RoHS
Color del producto
Black
Control de tomas
Lock-out, Recycle, Turn off, Turn on
Corriente máxima
32 A
Corriente máxima de entrada por fase
32 A
Corriente máxima total por fase
32 A
Enchufe
IEC309
Frecuencia de entrada de CA
50 - 60 Hz
Funciones de protección eléctrica
Overload
Huella de carbono total (kg de CO2e)
8595.81
Humedad relativa de almacenamiento (H-H)
5 - 95%
Humedad relativa de funcionamiento (H-H)
5 - 95%
Longitud del cable
3 m
Monitorización
Current, Power, Voltage
Montaje
Vertical
Número de tomas de CA
24 AC outlet(s)
Peso
8.23 kg
Peso del embalaje
10.5 kg
Potencia máxima
7680 W
Profundidad
51 mm
Profundidad del embalaje
118 mm
Temperatura de almacenamiento (T-T)
-25 - 65 °C
Temperatura de funcionamiento (T-T)
-5 - 45 °C
Tensión nominal de entrada
230 V
Tensión nominal de salida
230 V
Tipo
Single-phase
Tipos de PDU
Metered, Metered-by-outlet, Switched
Tipos de tomas de CA
C13 coupler, C19 coupler
Historial de precios de los últimos 6 meses
APC Rack PDU 2G, Metered by Outlet con conmutación, ZeroU, 32A, 230V, (21) C13 y (3) C19
Actual
2.091,48 €
Mínimo
2.027,21 €
Máximo
2.216,43 €
Variación 24 h
+4,86 €   +0%
Semana
-24,07 €   -1%
Mes
+15,11 €   +1%