ATEN 1U 10A 12 puertos PDU básica

ATEN 1U 10A 12 puertos PDU básica
ATEN 1U 10A 12 puertos PDU básica
ATEN 1U 10A 12 puertos PDU básica
ATEN 1U 10A 12 puertos PDU básica
65,87 €
The ATEN Basic PDU ATEN PE0112G-AT-G is a 1U rack-mountable power distribution unit providing 12 C13 AC outlets in a compact aluminium housing. Designed for efficient use of rack space, the unit includes a 3 m power cord (LINP-10F3-2B0G), supports an input voltage range of 100–240 V and a maximum cu... Leer más
Stock 2 Código 1728750 Marca ATEN Modelo PE0112G-AT-G Garantía 2 años

Envíos y devoluciones

Entrega estimada Viernes, Octubre 16
Te mantendremos informado a través de nuestro sistema de seguimiento detallado
Opciones de pago
Tarjeta bancariaVisaMastercardPayPalApple PayGoogle PayTransferencia bancaria

The ATEN Basic PDU ATEN PE0112G-AT-G is a 1U rack-mountable power distribution unit providing 12 C13 AC outlets in a compact aluminium housing. Designed for efficient use of rack space, the unit includes a 3 m power cord (LINP-10F3-2B0G), supports an input voltage range of 100–240 V and a maximum current of 10 A, and carries CE certification. Dimensions are 480 mm (W) × 450 mm (D) × 44 mm (H) and the product weight is 0.92 kg.

Advantages

The 1U vertical design allows installation on the outside of a rack to save internal rack space while keeping all 12 AC outlets accessible. The aluminium housing provides durability and effective heat dissipation. Wide input voltage compatibility (100–240 V) and CE certification ensure compatibility with international power environments. The included 3 m power cord simplifies installation and reduces the need for additional cables.

Suitable for

  • Server rooms and data centre racks requiring compact power distribution
  • Network cabinets and telecommunications enclosures
  • Small to medium-sized IT closets and edge computing racks
  • Environments needing multiple C13 outlets in limited space

Key specifications

  • Model: PE0112G-AT-G
  • Outlets: 12 × C13 (AC)
  • Input voltage: 100–240 V
  • Maximum current: 10 A
  • Cable: LINP-10F3-2B0G, 3 m
  • Housing: Aluminium, black
  • Dimensions (W×D×H): 480 × 450 × 44 mm
  • Weight: 0.92 kg
  • Certifications: CE

How to use

Mount the PDU vertically on the outside of a 19-inch rack using appropriate mounting brackets or screws. Connect the unit to a suitably rated AC power source using the supplied 3 m power cord. Plug equipment into the 12 C13 outlets, ensuring the total current draw does not exceed the 10 A maximum. Position the PDU to allow adequate ventilation around the aluminium housing and route cables to avoid strain on connectors.

Recommendations

Distribute connected equipment across outlets to avoid exceeding the 10 A rating; verify total load before powering on. Use the PDU in environments within the specified input voltage range (100–240 V) and maintain clearance for airflow around the unit. For permanent installations, secure power and device cabling to prevent accidental disconnections.
Aspectos destacados
  • Server rooms and data centre racks requiring compact power distribution
  • Network cabinets and telecommunications enclosures
  • Small to medium-sized IT closets and edge computing racks
  • Environments needing multiple C13 outlets in limited space
  • Model: PE0112G-AT-G
  • Outlets: 12 × C13 (AC)
  • Input voltage: 100–240 V
  • Maximum current: 10 A
  • Cable: LINP-10F3-2B0G, 3 m
  • Housing: Aluminium, black
  • Dimensions (W×D×H): 480 × 450 × 44 mm
  • Weight: 0.92 kg
  • Certifications: CE
Especificaciones
Altitud de funcionamiento
0 - 3000 m
Altura
44 mm
Altura de la caja exterior
188 mm
Altura del embalaje
82 mm
Ancho
480 mm
Ancho de la caja exterior
595 mm
Ancho del embalaje
112 mm
Cables incluidos
AC
Capacidad de carga
2400 VA
Capacidad del rack
1U
Certificación
CE Class A CE,LVD
Color del producto
Black
Corriente máxima
10 A
Frecuencia de entrada de CA
50 - 60 Hz
Funciones de protección eléctrica
Over current
Longitud de la caja exterior
710 mm
Longitud del cable
3 m
Manual
Yes
Material de la carcasa
Aluminium
Número de tomas de CA
12 AC outlet(s)
Peso
920 g
Peso bruto de la caja exterior
13 kg
Peso del embalaje
1.18 kg
Peso neto de la caja exterior
9.2 kg
Productos por caja exterior
10 pc(s)
Profundidad
450 mm
Profundidad del embalaje
697 mm
Temperatura de almacenamiento (T-T)
-20 - 60 °C
Temperatura de funcionamiento (T-T)
0 - 40 °C
Tensión nominal de entrada
100 -240 V
Tensión nominal de salida
240 V
Tipos de PDU
Basic
Tipos de tomas de CA
C13 coupler
Historial de precios de los últimos 6 meses
ATEN 1U 10A 12 puertos PDU básica
Actual
65,87 €
Mínimo
63,35 €
Máximo
84,53 €
Variación 24 h
+2,23 €   +4%
Semana
+0,08 €   +0%
Mes
-1,64 €   -2%

Productos populares en esta categoría

Hola, soy el asistente de IA de DistriNode. Puedo ayudarte a encontrar productos, comparar opciones, crear presupuestos en PDF o abrir solicitudes de soporte.