Cable de detección de incendios BITNER YnTKSYekw 2x2x0,8, 100 m de longitud

Cable de detección de incendios BITNER YnTKSYekw 2x2x0,8, 100 m de longitud
Cable de detección de incendios BITNER YnTKSYekw 2x2x0,8, 100 m de longitud
74,08 €
BITNER YnTKSYekw 2x2x0,8 fire signalling cable on a 100 m reel is designed for wired connections in fire alarm and detection systems. The cable contains two twisted pairs of conductors with a conductor diameter of 0.8 mm, arranged to transmit control and signalling signals between detectors, control... Leer más
Stock 6 Código 1715354 Marca BITNER Modelo 41369K Garantía 2 años

Envíos y devoluciones

Entrega estimada Viernes, Octubre 16
Te mantendremos informado a través de nuestro sistema de seguimiento detallado
Opciones de pago
Tarjeta bancariaVisaMastercardPayPalApple PayGoogle PayTransferencia bancaria

BITNER YnTKSYekw 2x2x0,8 fire signalling cable on a 100 m reel is designed for wired connections in fire alarm and detection systems. The cable contains two twisted pairs of conductors with a conductor diameter of 0.8 mm, arranged to transmit control and signalling signals between detectors, control panels, sounders and other low-voltage fire safety devices. The construction is intended for fixed installations in buildings and technical facilities where reliable signal transmission and clear pairing are required.

Advantages

The cable offers stable electrical characteristics for short- and medium-distance signalling runs and maintains signal integrity through paired conductors that reduce interference. A 100 m reel simplifies handling and installation planning for typical fire protection circuits. The product is suitable for fixed wiring with straightforward routing and termination using standard tools and connectors compatible with fire alarm equipment.

Suitable for

Key specifications

How to use

Plan the routing route from detectors to the control panel and measure required lengths allowing extra for terminations. Strip the outer sheath and separate conductors carefully to avoid nicking the copper. Use appropriate fire-alarm compatible connectors or terminal blocks to terminate each pair, maintaining pair integrity to preserve signal quality. Secure the cable along cable trays, conduits or mounting points according to building regulations and fire safety standards, avoiding sharp bends and mechanical stress. Test continuity and signal transmission after installation and before commissioning the fire alarm system.

Recommendations

Install the cable in accordance with local electrical and fire safety codes. Keep separation from high-voltage power lines to reduce electromagnetic interference and route in protected pathways where possible. Use junction boxes or approved connectors for splices, and verify compatibility with the fire alarm control panel and peripheral devices prior to final connection.

Aspectos destacados
  • Wiring between fire detectors and fire control panels
  • Connections to sounders, sirens and notification devices in alarm systems
  • Short- to medium-length signalling runs inside commercial and residential buildings
  • Fixed low-voltage installations in technical rooms and service shafts
  • Conductor configuration: two twisted pairs (2x2)
  • Conductor diameter: 0.8 mm
  • Cable type: signalling/control for fire alarm systems
  • Length: 100 m reel
  • Application: fixed indoor installation for low-voltage signalling
Historial de precios de los últimos 6 meses
Cable de detección de incendios BITNER YnTKSYekw 2x2x0,8, 100 m de longitud
Actual
74,08 €
Mínimo
68,53 €
Máximo
84,11 €
Variación 24 h
+0,38 €   +1%
Semana
-0,28 €   0%
Mes
+4,95 €   +7%
Hola, soy el asistente de IA de DistriNode. Puedo ayudarte a encontrar productos, comparar opciones, crear presupuestos en PDF o abrir solicitudes de soporte.