CyberPower PDU81405 unidad de distribución de energía (PDU) 24 salidas AC 0U negro

CyberPower PDU81405 unidad de distribución de energía (PDU) 24 salidas AC 0U negro
CyberPower PDU81405 unidad de distribución de energía (PDU) 24 salidas AC 0U negro
CyberPower PDU81405 unidad de distribución de energía (PDU) 24 salidas AC 0U negro
CyberPower PDU81405 unidad de distribución de energía (PDU) 24 salidas AC 0U negro
CyberPower PDU81405 unidad de distribución de energía (PDU) 24 salidas AC 0U negro
CyberPower PDU81405 unidad de distribución de energía (PDU) 24 salidas AC 0U negro
963,08 €
CyberPower PDU81405 is a network-grade, single-phase metered and monitored power distribution unit with switched outlet control, designed for data centers and enterprise server rooms. The 0U rack-mount PDU provides 24 AC outlets (C13/C19 compatible), supports a nominal input voltage of 200–240 V and... Leer más
Stock AgotadoSin stock Código 109136 Marca CyberPower Modelo PDU81405 Garantía 2 años

Envíos y devoluciones

CyberPower PDU81405 is a network-grade, single-phase metered and monitored power distribution unit with switched outlet control, designed for data centers and enterprise server rooms. The 0U rack-mount PDU provides 24 AC outlets (C13/C19 compatible), supports a nominal input voltage of 200–240 V and a maximum current of 16 A, and includes a color-configurable, rotatable LCD for local status and metering. The unit supports remote monitoring and control over the network, event logging, and firmware updates via USB. An optional environmental sensor can be connected to the RJ45 port for real-time temperature and humidity monitoring.

Advantages

The PDU81405 combines metering, monitoring and switched outlet control in a single 0U form factor, enabling per-outlet on/off control for remote reboot and scheduled power cycles. A daisy-chain feature permits multiple PDUs to be managed under one IP address. Network connectivity works with PowerPanel management software and standard web/SNMP interfaces for real-time monitoring, event logging and notifications by email, SMS or SNMP trap. The hot-swappable Ethernet module and USB port simplify firmware upgrades and serviceability, while the configurable LCD helps quickly identify and categorize connected equipment.

Suitable for

  • Data centers and server rooms
  • Network closets and edge computing racks
  • Enterprise IT infrastructures requiring per-outlet control and monitoring
  • Environments where temperature and humidity monitoring is needed (with optional sensor)

Key specifications

  • Model: CyberPower PDU81405
  • PDU type: Switched, Monitored, Metered
  • Form factor: 0U, rack-mount
  • AC outlets: 24 (C13 / C19 compatible)
  • Nominal input voltage: 200–240 V
  • Maximum current: 16 A
  • Product colour: Black
  • Weight: 7 kg

How to use

Install the PDU81405 vertically in a compatible rack space using the 0U mounting method according to your rack supplier’s instructions. Connect the input power to a suitable 200–240 V, 16 A supply and distribute load devices to the C13/C19 outlets as required. Configure network settings through the web interface or PowerPanel software, update firmware via the USB port if needed, and connect an optional ENVIROSENSOR to the RJ45 port for environmental monitoring. Use the LCD to view local metering and status, and manage individual outlets remotely for reboots or scheduled power actions.

Recommendations

To ensure reliable operation, keep the total connected load within the 16 A limit, follow rack installation best practices for ventilation and cable management, and configure event notifications so that administrators receive immediate alerts for power anomalies. Use the daisy-chain function to simplify management of multiple PDUs and attach the optional environmental sensor to monitor temperature and humidity in critical areas.
Aspectos destacados
  • Data centers and server rooms
  • Network closets and edge computing racks
  • Enterprise IT infrastructures requiring per-outlet control and monitoring
  • Environments where temperature and humidity monitoring is needed (with optional sensor)
  • Model: CyberPower PDU81405
  • PDU type: Switched, Monitored, Metered
  • Form factor: 0U, rack-mount
  • AC outlets: 24 (C13 / C19 compatible)
  • Nominal input voltage: 200–240 V
  • Maximum current: 16 A
  • Product colour: Black
  • Weight: 7 kg
Especificaciones
Altitud de funcionamiento
0 - 3500 m
Altitud fuera de funcionamiento
0 - 15000 m
Altura
48 mm
Altura del embalaje
115 mm
Ancho
1665 mm
Ancho del embalaje
1895 mm
Capacidad del rack
0U
Certificación
CE, EN 55032 Class A
Color del producto
Black
Conexión en cadena
Yes
Corriente máxima
16 A
Enchufe
IEC 60309
Firmware actualizable
Yes
Firmware actualizable mediante
USB
Frecuencia de entrada de CA
50 / 60 Hz
Humedad relativa de almacenamiento (H-H)
0 - 95%
Humedad relativa de funcionamiento (H-H)
0 - 95%
Indicadores LED
Yes
Longitud del cable
3.05 m
Material de la carcasa
Metal
Montaje
Vertical
Número de puertos serie
1
Número de tomas de CA
24 AC outlet(s)
Pantalla
LCD
Peso
7 kg
Peso del embalaje
8.9 kg
Profundidad
56 mm
Profundidad del embalaje
185 mm
Protocolos de red compatibles
IPv4/v6, SNMPv1/v3, HTTP/HTTPs, TCP/IP, UDP, DHCP, NTP, DNS, SMTP, SSH, SSL, TLS, Telnet, FTP, and Syslog
Puertos Ethernet LAN (RJ-45)
3
Temperatura de almacenamiento (T-T)
-15 - 60 °C
Temperatura de funcionamiento (T-T)
0 - 55 °C
Tensión nominal de entrada
200-240 V
Tipo
Single-phase
Tipos de PDU
Metered, Monitored, Switched
Tipos de tomas de CA
C13 coupler, C19 coupler

Folleto

Abrir documento
El historial de precios aún no está disponible
Todavía estamos recopilando suficientes datos de precios diarios de este producto.

Productos populares en esta categoría

Vendedor: UAB KUR LT · Laisvės pr. 125A, LT-06118 Vilna, Lituania · Código de empresa 303192950 · NIF-IVA UE LT100008198612 · Envío desde la UE (Lituania)
Messenger
Hola, soy el asistente de IA de DistriNode. Puedo ayudarte a encontrar productos, comparar opciones, crear presupuestos en PDF o abrir solicitudes de soporte.