APC NetShelter Rack PDU Advanced Gen 2, Metered, de 3 fases, 11 kW 400 V 16 A o 11,5 kW 415 V 20 A, 520P6, 42 salidas

APC NetShelter Rack PDU Advanced Gen 2, Metered, de 3 fases, 11 kW 400 V 16 A o 11,5 kW 415 V 20 A, 520P6, 42 salidas
APC NetShelter Rack PDU Advanced Gen 2, Metered, de 3 fases, 11 kW 400 V 16 A o 11,5 kW 415 V 20 A, 520P6, 42 salidas
1.587,52 €
APC NetShelter Rack PDU Advanced (11K Series) provides reliable power distribution to IT equipment within server and/or networking racks. PDU level power metering provides power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, o... Leer más
Stock 13 Código 2408240 Marca APC Modelo APDU11250ME Garantía 3 años
CategoríaUnidades de distribución de energía (PDU)

Envíos y devoluciones

Entrega estimada lunes, 2 de noviembre
Te mantendremos informado a través de nuestro sistema de seguimiento detallado
Opciones de pago
Tarjeta bancariaVisaMastercardPayPalApple PayGoogle PayTransferencia bancaria

APC NetShelter Rack PDU Advanced (11K Series) provides reliable power distribution to IT equipment within server and/or networking racks. PDU level power metering provides power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparalleled deployment flexibility. Maximum outlet density with 42 outlets in a 2.2 in. (5.6 cm) wide form factor allows for more equipment in the rack. Outlets on the PDUs are color coded and labeled by breaker. Live Swap the NMC3 to minimize downtime in the unlikely event of an NMC power event. The rack PDU integrates with EcoStruxure IT through an NMC3 and can be accessed and configured via web, SNMP, and command line interface (CLI). A 10-foot (3-meter) input cord makes it easier for the PDU to reach the power supply. Rated to operate up to 60 C (140 F) at full load ensures reliability and availability even in today's high-density deployments. One gigabit Ethernet/network port (10/100/1000) enhances and standardizes network connectivity. Two link ports are available to cascade to up to 32 PDUs, with a network port sharing (NPS) feature to enable power sharing between Rack PDUs in the cascading group. Track or bill power usage confidently with 1% metering accuracy. Two environmental sensor ports allow for optional sensors (sold separately) to be connected. For data center deployments across multiple regions, these PDUs have the following certifications: UL, CE, CSA, UKCA, Nemiko, PSE, KC, China RoHS, RCM, and CMIM. This model’s input power cord is IEC-309 20 A 3P+N+PE and features 21 count C13/C15/C19/C21 combo outlets and 21 count C13/C15 outlets.

APC NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet. PDU types: Metered, Rack capacity: 0U, Type: Three-phase. AC outlets quantity: 40 AC outlet(s), AC outlet types: C13 coupler, C15 coupler, C19 coupler, C21 coupler. Management platform: NMC3. Nominal input voltage: 400 V, Maximum current: 20 A, AC input frequency: 50/60 Hz. Compliance certificates: RoHS, Certification: UKCA, CE, EN 62368-1, RoHS

Aspectos destacados
  • Ideal for high-density applications
  • Next-gen PDU speeds up IT deployments — one PDU for every type of device
  • 4-in-1 combination outlet design acts as C13, C15, C19, and C21 in one outlet
  • Enhanced cybersecurity and EcoStruxure™ IT compatible
  • 1 year free subscription to Secure NMC3 System
Especificaciones
Altura
1490 mm
Altura del embalaje
1720 mm
Ancho
56 mm
Ancho del embalaje
116 mm
Capacidad de carga
11500 VA
Capacidad del rack
0U
Certificación
UKCA, CE, EN 62368-1, RoHS
Certificados de conformidad
RoHS
Color del producto
Black
Corriente máxima
20 A
Frecuencia de entrada de CA
50/60 Hz
Número de fases
3
Número de puertos USB
1
Número de tomas de CA
40 AC outlet(s)
Peso
6.2 kg
Peso del embalaje
8.2 kg
Plataforma de gestión
NMC3
Profundidad
75 mm
Profundidad del embalaje
208 mm
Puertos Ethernet LAN (RJ-45)
5
Tensión nominal de entrada
400 V
Tensión nominal de salida
400 V
Tipo
Three-phase
Tipos de PDU
Metered
Tipos de tomas de CA
C13 coupler, C15 coupler, C19 coupler, C21 coupler

Folleto

Abrir documento
Historial de precios de los últimos 6 meses
APC NetShelter Rack PDU Advanced Gen 2, Metered, de 3 fases, 11 kW 400 V 16 A o 11,5 kW 415 V 20 A, 520P6, 42 salidas
Actual
1.587,52 €
Mínimo
1.577,06 €
Máximo
1.717,79 €
Variación 24 h
+3,27 €   +0%
Semana
+6,59 €   +0%
Mes
-96,34 €   -6%

Escribir una opinión

Valoración *
Tu nombre se mostrará públicamente: puedes usar un apodo. Invitamos a los compradores a escribir opiniones; las revisamos antes de publicarlas y publicamos también las críticas.

Más productos APC en esta categoría

Productos populares en esta categoría

Vendedor: UAB KUR LT · Laisvės pr. 125A, LT-06118 Vilna, Lituania · Código de empresa 303192950 · NIF-IVA UE LT100008198612 · Envío desde la UE (Lituania)
Hola, soy el asistente de IA de DistriNode. Puedo ayudarte a encontrar productos, comparar opciones, crear presupuestos en PDF o abrir solicitudes de soporte.
Todas las categorías